series ME

600 Volt
Cu 16 up to 10 AWG
XLPE 90°C / LSZH
ICEA S 73-532

Control, signalling, measuring and protective equipment, electric controls of home installations. Use in closed environments with a high concentration of people (airports, hospitals, trains, cinemas, shopping centers, tunnels) and in control rooms with electronic equipment sensitive to the exposure of corrosive gases. Installed in conduits, trays, cable ladders, in direct open air or indoors, buried in a trench or in ducts.

Features

  • Temperature rating: 90ºC (operating), 130°C (overload), 250°C (short circuit)

  • Voltage rating: 600V AC

  • Construction requirements: As per ICEA S 73-532

  • Conductor requirements: As per ASTM B174

  • Conductor: Annealed electrolytic copper; flexible

  • Insulation: XLPE (crosslinked polyethylene)

  • Sheath: LSZH-HFFR (Low Smoke Zero Halogen - Halogen Free Flame Retardant) fire-retardant; sunlight and oils resistant

  • Fire requirements: As per ICEA T 30-520

  • Standard for halogen absence and corrosive gases: As per IEC 60754-1/2

  • Smoke transparency requirements: As per IEC 61034-1/2

  • Oilsrequirements: As per ICEA S 73-532

  • Outdoors requirements: As per UL 2556 (UV rays)

  • Water behaviour requirements: Suitable AD7 (Occasional water submersion)

Fire-retardant

Fire-retardant

Halogen free

Halogen free

Low smoke

Low smoke

Mineral oil resistant

Mineral oil resistant

UV resistant

UV resistant

Water immersion

Water immersion

Identification

Standard
Sheath Conductors
MulticonductorMethod 3 Table E-2

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

ELECTRICAL CHARACTERISTICS

Resistances and intensity of admissible currents

Gauge AWG Electrical resistance at 20°C in C.C. (Ohm/km) Electrical resistance at 75°C in AC. a 60Hz (Ohm/km) Current-carrying capacity (1)
2x 4x 7x 10x 19x 30x
1613.9917.841814.412.6998.1
148.7711.18252017.512.512.511.3
125.527.04302421151513.5
103.484.44403228202018

(1) Current-carrying capacity of cables with up to three conductors, installed in ducts or directly buried, up to an ambient temperature of 30ºC, according to chart 310.15 (B)(16) of the NFPA 70. As from four-conductors, we’ve additionally applied the correction factor for more than three conductors from the chart 310.15 (B)(3)(a) of the NFPA70.

DIMENSIONS & WEIGHT

Cable formation N° Cond. x gauge AWG External diameter mm Weight kg/km Code
2x167.782ME 0216
3x168.196ME 0316
4x168.8115ME 0416
5x169.6136ME 0516
7x1610.4169ME 0716
10x1614.0254ME 1016
12x1614.4287ME 1216
14x1615.1322ME 1416
19x1616.7409ME 1916
24x1619.4505ME 2416
30x1620.6603ME 3016
2x149.0116ME 0214
3x149.5138ME 0314
4x1410.4166ME 0414
5x1411.3199ME 0514
7x1412.3250ME 0714
10x1416.6363ME 1014
12x1417.1414ME 1214
14x1418.0469ME 1414
19x1420.0603ME 1914
24x1424.3806ME 2414
30x1425.7964ME 3014
2x129.9152ME 0212
3x1210.5184ME 0312
4x1211.5224ME 0412
5x1212.6272ME 0512
7x1214.5371ME 0712
10x1218.5493ME 1012
12x1219.1568ME 1212
19x1223.3896ME 1912
24x1227.11113ME 2412
30x1228.81343ME 3012
2x1011.2208ME 0210
3x1011.9256ME 0310
4x1013.0316ME 0410
5x1015.0411ME 0510
7x1016.4524ME 0710
10x1023.8983ME 1010
19x1026.41280ME 1910
24x1030.81595ME 2410
30x1032.71940ME 3010