series MH

600 Volt
Cu 14 AWG up to 750 MCM
XLPE 90°C / LSZH
ICEA S 95-658

Fixed power distribution networks in closed environments with a high concentration of people (airports, hospitals, trains, cinemas, shopping malls, tunnels) and in control rooms with electronic equipment sensitive to exposure to corrosive gases. For Alternating Current (60Hz), for single-phase systems (110V), three-phase systems (190/210V) and systems with voltages up to 600V. Installed in conduits, trays, cable ladders, in direct open air or indoors, buried in a trench or in ducts.

Features

  • Temperature rating: 90ºC (operating), 130°C (overload), 250°C (short circuit)

  • Voltage rating: 600V AC

  • Construction requirements: As per ICEA S 95-658

  • Conductor requirements: As per ASTM B172 to B174

  • Conductor: Annealed electrolytic copper; flexible

  • Insulation: XLPE (crosslinked polyethylene)

  • Sheath: LSZH-HFFR (Low Smoke Zero Halogen - Halogen Free Flame Retardant) fire-retardant; sunlight and mineral-oil resistant.

  • Fire requirements: As per ICEA T 30-520

  • Standard for halogen absence and corrosive gases: As per IEC 60754-1/2

  • Smoke transparency requirements: As per IEC 61034-1/2

  • Oils requirements: As per ICEA S 73-532

  • Outdoors requirements: As per UL 2556 (UV rays)

  • Water behaviour requirements: Suitable AD7 (Occasional water submersion)

Fire-retardant

Fire-retardant

Halogen free

Halogen free

Low smoke

Low smoke

Mineral oil resistant

Mineral oil resistant

UV resistant

UV resistant

Water immersion

Water immersion

Identification

Standard
Sheath Conductors
1 Conductor
2 Conductors
3 Conductors
4 Conductors

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

ELECTRICAL CHARACTERISTICS

Resistances, reactance and intensity of admissible currents

Conductor’s gauge (AWG) Flexible class conductors. Electrical resistance at 20°C en D.C. (Ohm/km) Flexible class conductors. Electrical resistance in C.C. at 90°C (Ohm/km) Reactancia inductiva a 60Hz (Ohm/Km) Current-carrying capacity (6)
1 Conductor (1) Unipolar (2) Unipolar (3) Multiconductor (4) 4 Conductors (5)
1 Conductor Multiconductor 1 Conductor Multiconductor
148.68.7710.9711.190.1360.1790.1210.0980.10525
125.415.526.97.040.1270.1710.1130.0920.09930
103.4093.484.354.430.1190.1630.1050.0860.09340
82.1442.192.732.790.1180.1620.1040.090.09755
61.371.41.751.780.110.1540.0960.0840.09175
40.8630.881.11.120.1050.1490.090.080.08795
20.5450.5560.6960.7090.10.1440.0860.0770.084130
10.430.4390.5490.560.1040.1480.090.0780.085145
1/00.3440.3510.440.4480.1010.1450.0870.0760.083170
2/00.2740.2790.3510.3580.0980.1420.0840.0740.081195
3/00.2170.2210.2780.2840.0960.1390.0810.0720.08225
4/00.1720.1750.2220.2260.0940.1370.0790.0710.079260
2500.1470.150.190.1940.0970.1410.0830.0720.079290
3000.1230.1250.160.1630.0950.1390.080.0710.078320
3500.1050.1070.1380.140.0940.1380.0790.070.078350
4000.09190.09370.1210.1240.0930.1360.0780.070.077380
4500.08170.08330.1090.1110.0910.1350.0770.0690.076405
5000.07350.0750.09910.10110.0910.1340.0760.0680.076430

(1) Three single conductor cables displayed in flat, in contact with each other. (2) Three single conductor cables displayed in flat, separated by 1 diameter between each other. (3) Three single-conductor cables displayed in a trefoil in contact with each other. (4) Calculation of Inductive reactance valid for two-conductor, three-conductor, and five-conductor cables. (5) Calculation of Inductive reactance valid for four-conductor cables. (6) Current-carrying capacity of cables with up to three conductors, installed in ducts or directly buried, up to an ambient temperature of 30ºC, according to chart 310.15 (B)(16) of the NFPA 70. As from four-conductors, we’ve additionally applied the correction factor for more than three conductors from the chart 310.15 (B)(3)(a) of the NFPA70.

DIMENSIONS & WEIGHT

Cable Formation N° Cond. x gauge AWG/MCM External diameter mm Weight kg/km Code
1 x 144.938MH 0114
1 x 125.352MH 0112
1 x 106.072MH 0110
1 x 87.5115MH 0108
1 x 68.6170MH 0106
1 x 49.7243MH 0104
1 x 211.1357MH 0102
1 x 113.3470MH 0101
1 x 1/014.2566MH 11/0
1 x 2/015.5710MH 12/0
1 x 3/016.7868MH 13/0
1 x 4/018.91123MH 14/0
1 x 25019.91345MH 1250
1 x 30023.51582MH 1300
1 x 35024.41853MH 1350
1 x 40025.62073MH 1400
1 x 50028.02561MH 1500
1 x 60031.22974MH 1600
1 x 70033.13388MH 1700
1 x 75034.03604MH 1750
2 x 149.0116MH 0214
2 x 129.9152MH 0212
2 x 1011.2207MH 0210
2 x 815.1363MH 0208
2 x 617.1512MH 0206
2 x 422.4858MH 0204
2 x 225.81209MH 0202
2 x 128.61489MH 0201
2 x 1/030.51752MH 21/0
2 x 2/033.02138MH 22/0
2 x 3/035.42560MH 23/0
2 x 4/039.83274MH 24/0
2 x 25041.93825MH 2250
2 x 30050.04816MH 2300
2 x 35051.85468MH 2350
2 x 40054.36078MH 2400
2 x 50059.17389MH 2500
2 x 60065.48701MH 2600
3 x 149.5138MH 0314
3 x 1210.5184MH 0312
3 x 1011.9256MH 0310
3 x 816.0444MH 0308
3 x 618.2640MH 0306
3 x 423.71058MH 0304
3 x 227.41512MH 0302
3 x 130.41867MH 0301
3 x 1/032.42215MH 31/0
3 x 2/035.12727MH 32/0
3 x 3/037.73288MH 33/0
3 x 4/044.04376MH 34/0
3 x 25047.75307MH 3250
3 x 30053.36120MH 3300
3 x 35055.17026MH 3350
3 x 40057.97825MH 3400
3 x 50063.09565MH 3500
3 x 60071.411459MH 3600
3 x 14+1x1410.4166MH 0314 0114
3 x 12+1x1211.5224MH 0312 0112
3 x 10+1x1013.0315MH 0310 0110
3 x 8+1x1016.6493MH 0308 0110
3 x 6+1x819.4731MH 0306 0108
3 x 4+1x825.11174MH 0304 0108
3 x 2+1x628.31644MH 0302 0106
3 x 1+1x630.81974MH 0301 0106
3 x 1/0+1x632.52303MH 31/0 0106
3 x 2/0+1x634.82789MH 32/0 0106
3 x 3/0+1x437.73415MH 33/0 0104
3 x 4/0+1x444.14520MH 34/0 0104
3 x 250+1x447.75444MH 3250 0104
3 x 300+1x353.36300MH 3300 0103
3 x 350+1x355.17207MH 3350 0103
3 x 400+1x357.98007MH 3400 0103
3 x 500+1x263.09785MH 3500 0102
3 x 600+1x271.411680MH 3600 0102