Clad series OF-H

Steel wire armour

0.6/1kV
Flexible Cu 1 up to 4mm²
Up to 48 Conductors
PVC 70°C / PVC

Control, signalling, measuring and protective equipment; electric controls of industrial installations. Installed in aerial trays, gutters or conduits, buried in ducts or directly buried. It has additional mechanical protection.

Features

  • Temperature ratings: 75ºC (operating), 160°C (short circuit)

  • Voltage rating: 600/1000 Volt A.C. – 1200 Volt A.C. (Max) – 1500 Volt D.C.

  • Construction requirements: IRAM 2178-1 – IEC 60502-1

  • Conductor requirements: IRAM NM 280 – IEC 60228

  • Conductor: Annealed electrolytic copper - Flexible stranding class 5

  • Insulation: PVC

  • Bedding: PVC

  • Armour: Galvanized steel wire armour

  • Sheath: Flame retardant PVC

  • Fire requirements: As per IEC 60332-3-24

Fire-retardant

Fire-retardant

Flexible stranded conductors

Flexible stranded conductors

Sequentially marked

Sequentially marked

Industrial applications

Industrial applications

Tray cable

Tray cable

Identification

Standard
Sheath Conductors
Multiconductor alphanumeric identification

Instalation

falta label en campo?
falta label en campo?
falta label en campo?

Constructive variants

The information provided corresponds to the standard version, and different alternatives of insulation and / or covering can be used upon request.

ELECTRICAL CHARACTERISTICS

Resistances and intensity of admissible currents

Nominal cross-section sq mm² Electrical resistance at 20ºC in C.C Ohm/km Electrical resistance at 90ºC in C.A. Ohm/km Current-carrying capacity in free air. At 40°C as per IEC 364-5-523. Formations in perforated trays or ladder type. (Ampere)
2x 4x 7x 10x 19x 30x 48x
119.523.3--------------
1.513.315.918.115.312.79.19.18.16.3
2.57.989.55252117.512.512.511.38.8
44.955.92332923.116.516.514.9--

As from seven-conductors, we’ve additionally applied the correction factor for more than three conductors the chart 310.15 (B)(3)(a) of the NFPA70.

DIMENSIONS & WEIGHT

Cable Formation N° Cond. x cross-section (mm²) Diameter under armour mm External diameter mm Weight kg/km Code
2x17.612.2273OF 0210 H
3x18.112.7298OF 0310 H
4x18.813.4330OF 0410 H
5x19.614.2369OF 0510 H
7x110.415.0421OF 0710 H
10x112.317.8622OF 1010 H
12x113.318.8685OF 1210 H
14x114.219.7747OF 1410 H
19x116.221.7897OF 1910 H
24x117.924.11168OF 2410 H
30x119.826.01345OF 3010 H
37x121.828.01542OF 3710 H
48x124.530.91840OF 4810 H
2x1.58.112.7301OF 0215 H
3x1.58.613.2330OF 0315 H
4x1.59.414.0367OF 0415 H
5x1.510.314.9417OF 0515 H
7x1.511.215.8478OF 0715 H
10x1.513.318.8701OF 1015 H
12x1.514.319.8785OF 1215 H
14x1.515.320.8857OF 1415 H
19x1.517.523.71161OF 1915 H
24x1.519.425.61333OF 2415 H
30x1.521.527.71557OF 3015 H
37x1.523.630.01804OF 3715 H
48x1.527.034.72464OF 4815 H
2x2.59.013.6349OF 0225 H
3x2.59.614.2387OF 0325 H
4x2.510.515.1439OF 0425 H
5x2.511.516.1502OF 0525 H
7x2.512.518.0701OF 0725 H
10x2.514.820.3856OF 1025 H
12x2.516.121.6959OF 1225 H
14x2.517.223.41189OF 1425 H
19x2.519.725.91433OF 1925 H
24x2.521.828.21686OF 2425 H
30x2.524.230.61971OF 3025 H
37x2.526.733.32291OF 3725 H
48x2.530.538.43115OF 4825 H
2x410.915.5453OF 0240 H
3x411.617.1619OF 0340 H
4x412.718.2709OF 0440 H
5x414.019.5810OF 0540 H
7x415.320.8946OF 0740 H
10x418.224.41282OF 1040 H
12x419.826.01446OF 1240 H
14x421.227.41608OF 1440 H
19x424.330.71982OF 1940 H
24x427.535.42685OF 2440 H
30x430.538.43129OF 3040 H
37x433.641.73725.093OF 3740 H